Bitzer two-stage reciprocating compressor systems for hydrocarbon extraction condensing, deep ethanol pre-cooling, and large-scale operations requiring -58°F (-50°C). Stainless steel reservoir, high-pressure vortex pumps, R-448A. Made in USA.

-58°F Min Temp / -50°C
Bitzer 2-Stage Stainless Reservoir Vortex Pump Made in USA
SLT Super Low Temp Series
Verified Performance Data

SLT Series — Cooling Capacity at 70°F Ambient

Ambient range 20°F–100°F. All capacities at 70°F ambient.

Model -58°F / -50°C -43.6°F / -42°C 31.1°F / -0.5°C Pump Connections Refrigerant Tank Dimensions (D x W x H) Weight Voltage FLA / MCA
AG4000-SLT 7,800 BTU/hr 13,800 BTU/hr 100,700 BTU/hr 2.2kW Vortex — 27.3 GPM max @ 13 PSI 3/4" NPT R-448A 15 Gal SS 36.75" x 67.75" x 66.13" 1,000 lbs 480V/3P 33A / 38.5A
AG5000-SLT 15,500 BTU/hr 29,500 BTU/hr 179,000 BTU/hr 3.75kW Vortex — 35.7 GPM max @ 31 PSI 1-1/2" NPT R-448A 15 Gal SS 49.75" x 69.38" x 75.63" 1,250 lbs 480V/3P 46A / 53.1A
AG10000-SLT 31,100 BTU/hr 58,900 BTU/hr 358,000 BTU/hr 7.5kW Vortex — 71.3 GPM max @ 25 PSI 1-1/2" NPT R-448A 30 Gal SS 49.75" x 69.38" x 75.63" 2,500 lbs 480V/3P 92A / 106.2A
AG15000-SLT 46,600 BTU/hr 88,400 BTU/hr 536,900 BTU/hr 3.75kW Vortex — 35.7 GPM max @ 31 PSI 2" NPT R-448A 50 Gal SS 49.75" x 69.38" x 75.63" 3,750 lbs 480V/3P 138A / 159.3A
AG20000-SLT 62,100 BTU/hr 117,900 BTU/hr 715,900 BTU/hr 3.75kW Vortex — 35.7 GPM max @ 31 PSI 2" NPT R-448A 50 Gal SS 49.75" x 69.38" x 75.63" 5,000 lbs 480V/3P 184A / 212.43A

All information for reference only. Specifications subject to change. Compressor: Bitzer 2 Stage Reciprocating on all SLT models.

Hydrocarbon Extraction

SLT + ULT Combination Systems

SLT condensing units paired with ULT subcoolers for complete butane/propane solvent recovery to -65°F (-54°C).

ConfigurationCapacity (70% Butane / 30% Propane)Subcooled Solvent Temp
AG4000-SLT + AG1000-ULT90 lbs/hr (1.5 lbs/min)-65°F (-54°C)
AG5000-SLT + AG1000-ULT120 lbs/hr (2 lbs/min)-65°F (-54°C)
AG5000-SLT + AG2000-ULT210 lbs/hr (3.5 lbs/min)-65°F (-54°C)
AG10000-SLT + AG2000-ULT300 lbs/hr (5 lbs/min)-65°F (-54°C)
AG10000-SLT + AG5000-ULT420 lbs/hr (7 lbs/min)-65°F (-54°C)
AG15000-SLT + AG5000-ULT600 lbs/hr (10 lbs/min)-65°F (-54°C)

Capacity = solvent mass flow rate, not biomass throughput.

Get Started

Request Spec Sheets or a Quote

Full spec sheets with complete electrical and dimensional data for all SLT models.

Chiller Sizing Calculator Request Spec Sheets
Resources

Related Guides

Guide
Hydrocarbon Extraction Cooling Requirements
Cooling for butane and propane hydrocarbon extraction — solvent subcooling to −65°F, why SLT+ULT systems are paired,…
Guide
How to Size an Industrial Chiller
How to size an industrial chiller: heat load, flow rate, temperature differential, and ambient conditions — and how…
FAQ

Common Questions

How cold does the SLT (Super Low Temp) series go?

SLT reaches about −58°F (−50°C) — hydrocarbon condensing and deep ethanol pre-cooling.

How is SLT different from ULT?

SLT is a two-stage system for the −50°C range; ULT uses cascade refrigeration to reach −80°C.